A chart lookup is only the first step. Concentration, temperature, pressure, velocity, exposure time, and pump construction all change the result. A material that handles 10% sulfuric acid may fail in 93%.
This article gives you a quick-reference chart built on supplier data, a framework for choosing materials, seal considerations, validation steps, and the consequences of getting it wrong.
Key Takeaways
- Compatibility means resisting corrosion, swelling, dissolution, permeation, or embrittlement in your specific fluid.
- Check every wetted part: casing, impeller, shaft, liners, seals, and elastomers.
- Concentration, temperature, mixtures, solids, and duty cycle can flip a rating.
- Treat charts as screening tools and verify critical duties with current supplier data.
- Select the pump construction and seal arrangement together.
What Chemical Compatibility Represents in Pump Materials
Chemical compatibility is a material's ability to keep its chemical, mechanical, dimensional, and sealing properties when exposed to the pumped fluid under stated operating conditions.
It is a system-level question. The least-resistant wetted component sets the reliability of the whole pump. A resistant casing paired with the wrong O-ring still leaks.
Factors That Influence Compatibility in Real-World Operation
Fluid composition. Use the exact process-fluid makeup, not a broad chemical name. Concentration, pH, purity, and contaminants all change the attack mechanism. Iwaki notes that individually compatible liquids can become incompatible when mixed, and trace impurities can inhibit or accelerate attack.
Operating conditions. Temperature, pressure, velocity, solids loading, cavitation, and start-stop cycles all matter. Heat and high velocity speed up both chemical attack and erosion.
Construction and aging. Material grade, welds, cast surfaces, tolerances, residual stress, lining condition, and seal wear all play a part. In Haynes' laboratory tests of C-276 in 10% HCl at 100 °F, weld metal and base metal corroded at different rates (8.7 versus 6.7 mpy). Fabrication condition matters.

Chemical Compatibility Range and Pump Materials Chart
Verify before you specify: Every rating below is a screening value. Confirm it against current supplier data for your actual application.
Compatibility Rating Framework
The chart below uses Finish Thompson's June 2025 Chemical Resistance Guide. Each number is the maximum chemical/material temperature, not a complete-pump operating rating.
- NR: not recommended
- Numbers: maximum temperature in °F (°C)
- Ratings are not continuous-service guarantees, and the pump model may have a lower limit than the chemical/material chart.
- "GF-PP" means glass-filled polypropylene only, not all PP grades.
Pump Material Comparison
| Material | Strengths | Limitations and boundaries |
|---|---|---|
| 316/316L stainless | Moderate-duty general service | NR for 37% HCl in the guide; chloride-contaminated acids need better alloys |
| Duplex 2205 | Outperforms 316L in chloride-contaminated sulfuric acid | No concentration-independent limit |
| Alloy 20 | Hot sulfuric acid; many environments that attack 316 | Chlorides can increase attack |
| Hastelloy C-276 | Oxidizing and nonoxidizing acids; chloride pitting resistance | Limits are chemical-specific |
| Hastelloy B-3 | Pure HCl and sulfuric acid | Not valid for contaminated acid |
| Polypropylene | Economical sealless construction | One DB-series pump tops out at 180 °F (82 °C) |
| PVDF | Broad acid and halogen resistance | DB maximum 220 °F (104 °C); Tapflo CTP 194 °F (90 °C) |
| PTFE/PFA lining | Corrosive and hazardous media | Richter's lined family spans -80 to 400 °F (-60 to 200 °C) |
Polymer temperatures here are pump-model specifications, not resin limits.
Chemical-by-Chemical Quick Reference
Maximum temperatures in °F / °C. Source: Finish Thompson guide, revised June 11, 2025.
| Chemical | GF-PP | PVDF | PTFE | 316 SS | C-276 |
|---|---|---|---|---|---|
| Sulfuric acid, 10% | 212/100 | 287/141.7 | 500/260 | NR | 165/73.9 |
| Sulfuric acid, 93% | NR | 200/93.3 | 500/260 | NR | 210/98.9 |
| Hydrochloric acid, 37% | 176/80 | 194/90 | 500/260 | NR | 140/60 |
| Sodium hydroxide, 50% | 180/82.2 | NR | 500/260 | 212/100 | 200/93.3 |
| Sodium hypochlorite, 12.5% | NR | 275/135 | 500/260 | NR | 140/60 |
| Nitric acid, 10% | NR | 280/137.8 | 500/260 | 181/82.8 | 185/85 |
| Phosphoric acid, 85% | 212/100 | 316/157.8 | 500/260 | 150/65.6 | 150/65.6 |
| Acetic acid, 10% | 212/100 | 225/107.2 | 500/260 | 390/198.9 | 257/125 |
| Ammonium hydroxide, 10% | 225/107.2 | 280/137.8 | 500/260 | 70/21.1 | 200/93.3 |
| Hydrogen peroxide, 30% | NR | 212/100 | 500/260 | 125/51.7 | 200/93.3 |
| Ferric chloride (concentration not stated) | 180/82.2 | 275/135 | 500/260 | NR | 175/79.4 |
Notes on reading the table:
- Concentration drives results. Sulfuric acid at 10% versus 93% flips glass-filled PP from 212 °F to NR.
- Chloride-rich fluids, oxidizers, and strong alkalis each create distinct problems. PVDF is NR in 50% caustic, while 316 handles it to 212 °F.
- The ammonia row covers aqueous ammonium hydroxide, not anhydrous ammonia.
- Ferric chloride lacks a stated concentration, so don't use it for final selection.

Seal and Elastomer Compatibility
A compatible casing does not guarantee a compatible seal. Check each seal part for chemical exposure, temperature, pressure, lubrication, and leakage consequences.
- EPDM: 50% NaOH to 212 °F (100 °C); 12.5% sodium hypochlorite only to 70 °F (21.1 °C)
- FKM: NR in 50% NaOH; 12.5% sodium hypochlorite to 130 °F (54.4 °C)
- Tungsten carbide: cobalt-bonded and nickel-bonded grades behave differently, per EagleBurgmann
- Silicon carbide, carbon, ceramic: resistance depends on the exact grade
- Nitrile and FFKM: get supplier data for your fluid
Seal springs, faces, and O-rings are often specified separately, so a plastic casing doesn't settle the seal.
Safe Operating Margin and Special Constructions
A material rated right at its concentration or temperature limit leaves no room for process swings. No universal safety margin exists, so ask the supplier what margin they support.
When standard metallic or single-seal pumps fall short, consider:
- Polymer-lined or fully non-metallic pumps
- Double seals with barrier fluid
- Sealless magnetic-drive pumps. ASME B73.3 covers metallic and lined sealless designs, but sealless doesn't mean chemically immune.

Call for testing or engineering review rather than a chart lookup when the fluid is toxic, highly oxidizing, hot, mixed, or safety-critical.
Key Technical Properties and How Compatibility Is Validated
Compatibility is both a material property and a pump-selection requirement. Document it and validate it before commissioning.
Resistance to Chemical Attack
- General corrosion: uniform wall loss on casings
- Pitting and crevice corrosion: localized attack at gaskets, welds, and joints. Crevice attack generally starts at substantially lower temperatures than pitting.
- Stress corrosion cracking: shafts and stressed metal parts
- Permeation, swelling, embrittlement: linings and elastomers
Thermal and Mechanical Suitability
Chemical ratings only hold within the material's temperature, pressure, strength, and dimensional-stability limits. Separate short-term exposure from continuous limits, and ask for supplier derating data. One DB-series pump lists up to 90 psi working pressure plus separate temperature maxima, but no curve shows both at once.
Erosion, Abrasion, and Hydraulic Effects
Corrosion combined with velocity, solids, and cavitation accelerates damage, especially in impeller passages. KSB separates erosive wear, erosion-corrosion, and cavitation erosion. A resistant polymer may also carry different mechanical and hydraulic limits than metal.
Seal Integrity and Containment
Elastomer swelling, thermal distortion, poor lubrication, shaft movement, and pressure swings all decide whether the pump stays leak-tight. Single seals suit benign fluids. Double seals with barrier fluid or sealless designs suit toxic or hazardous media.
Specification and Documentation
Put these on the material specification:
- Exact chemical name or composition and concentration range
- Temperature range and pressure
- Flow, head, and viscosity
- Solids and vapor pressure
- Duty cycle and cleaning fluids
- Required containment level
Label values as rated, recommended, conditional, tested, or estimated in datasheets, drawings, and supplier correspondence.
Measurement, Testing, and Engineering Validation
- Manufacturer compatibility data and seal supplier confirmation
- Immersion or coupon testing (ASTM G31 for metals, ASTM D471 for rubber)
- Ferric-chloride pitting tests (ASTM G48)
- Inspection of used components and pilot trials where justified

Field warning signs include:
- Wall-thickness loss
- Discoloration, swelling, or hardness change
- Leakage, vibration, or performance loss
- Seal-fluid contamination
Chemitek reviews applications for its custom-designed horizontal centrifugal process pumps. Send your chemical, concentration, temperature, flow, head, and duty-cycle data so its engineers can evaluate the fit.
Implications of Operating Outside the Recommended Range
The chain is predictable. Incompatible exposure causes corrosion or swelling, which cuts strength and changes dimensions. Seals then leak, hydraulic performance drops, product gets contaminated, and the line goes down.

Performance, Safety, and Compliance Consequences
- Reduced flow or head, imbalance, and vibration
- Bearing and seal damage
- Chemical release and worker exposure
- Product contamination
Flowserve links mating-face corrosion to concentricity problems and calls for shutdown on significant leakage.
Depending on your process, US rules may apply, including OSHA's process safety management standard (29 CFR 1910.119), OSHA Hazard Communication (1910.1200), EPA's Risk Management Program (40 CFR 68), and EPA's pump leak standards (40 CFR 61.242-2). Confirm which apply to your facility.
Common Misinterpretations of Chemical Compatibility Charts
- Treating "compatible" as an unconditional guarantee
- Applying a room-temperature rating to a hot process
- Checking only the casing and ignoring elastomers and small wetted parts
- Applying pure-chemical data to a process mixture
- Choosing the most resistant material without checking pressure, strength, hydraulics, cost, or availability
Conclusion
Chemical compatibility is a governing selection parameter for every pump material choice. Every wetted component must match the exact chemical and operating envelope.
Charts are a good starting point. Manufacturer data, application-specific validation, and engineering judgment make the final call.
Frequently Asked Questions
What are the different types of chemical pumps?
Common categories include centrifugal, metering, diaphragm, peristaltic, and magnetic-drive pumps. The pumped chemical and operating conditions still determine material compatibility.
What pump standards apply to chemical pumps (ASME, API 675)?
ASME B73.1 covers horizontal end-suction chemical process pumps, and B73.3 covers sealless versions. API 675 applies to controlled-volume metering pumps. Verify which standard matches your pump type.
What are the different types of pump couplings?
Common types include flexible, gear, grid, elastomeric, rigid, and magnetic couplings. Couplings are drive components and are not normally selected from a wetted-material chart.
How do I use a chemical compatibility chart for pump materials?
Identify the exact chemical and concentration, then check actual temperature and duty. Review every wetted component, confirm conditional ratings with suppliers, and keep a safety margin.
How do temperature and concentration affect pump material compatibility?
Both can speed corrosion, change polymer behavior, and alter seal performance. Never apply a room-temperature or single-concentration rating automatically.
Which pump material is best for corrosive chemicals?
No material wins universally. Compare metallic, polymer, lined, and sealless options against your chemical, concentration, temperature, pressure, solids, and containment needs.